Fixes are available
APAR status
Closed as program error.
Error description
When using the CLI; configuring the remote-address property for an xslproxy can cause a restart if the port is not specified; e.g. xslproxy test remote-address 127.0.0.1 exit
Local fix
Always make sure to specify a port.
Problem summary
Affected is XSLProxy configuration. When configuring via CLI it is allowed to create the proxy with a remote-address but without remote-port. This pattern causes an unexpected restart.
Problem conclusion
Fix is available in 7.0.0.10 and 7.1.0.7 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT11082
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-09-04
Closed date
2015-10-23
Last modified date
2015-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R710 PSY
UP