IT09932: PUREAPPLICATION SYSTEM: MONITORING AGENT INCORRECTLY PRODUCES KQ8_TEMPERATURE.EXCEEDTEMPERATURE WARNINGS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PureApplication System version 2.1.0.0
    -
    The PureApplication System events do not show any temperature
    problems for this component, yet the
    Monitoring Agent for IBM PureApplication Software
    reports:
    
    KQ8_Temperature_High_Cri situationDescriptionThe
    temperature has exceeded the maximum exhaust temperature.
    -
    The Monitoring Agent for IBM PureApplication Software has
    incorrectly reported this information.
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    Keywords: KQ8 Temperature HighCri situation Description The
    temperature has exceeded the maximum exhaust temperature.
    

Local fix

  • Always check the "Events", "Problem" and Hardware >
    Infrastructure pages in the System Console
    

Problem summary

  • The condition generating the warning should compare
    the current temperature to the maximum threshold
    temperature instead of the last maximum temperature.
    

Problem conclusion

  • A code fix is being provided in PureApplication System
    version 2.2.0.0 in the System Monitoring Pattern version
    1.0.7.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT09932

  • Reported component name

    PUREAPP SYS P H

  • Reported component ID

    5725F46HW

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-07-08

  • Closed date

    2016-02-17

  • Last modified date

    2016-02-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PAPP SYS 8382 I

  • Fixed component ID

    5725G3200

Applicable component levels

  • R220 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0.0"}]

Document Information

Modified date: