IBM Support

IT09668: CURSOR LEAK IN HEALTHCHECK TOOL

Direct link to fix

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running the Healthcheck Tool it is possible to run into the
    error: ORA-01000 maximum open cursors exceeded.
    

Local fix

  • STRRTC - 469656
    JPM
    

Problem summary

  • Problem Description:
    Some of the HealthCheck Tool database queries leave open cursors
    that affect performance and memory over time, eventually
    leading to a maximum open cursors exceeded error (ORA-0100).
    
    Platforms Affected:
    Oracle database
    
    Users Affected:
    Users of HealthCheck Tool V1.0.2.1 and earlier
    

Problem conclusion

  • Resolution Summary:
    A code fix has been provided.
    
    Delivered In:
    5020500_7 (HealthCheck Tool V1.0.2.2)
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT09668

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    524

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-06-24

  • Closed date

    2015-07-23

  • Last modified date

    2015-07-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
28 August 2023