Error description
TPC 5.2.5 fails at TPC Web GUI component at ant target deployWebServer with the following error. The root cause is that some files are not copied successfully from the WebServer.ear in the TPC cd image to the TPC installation directory. ADMA5016I: Installation of WebServer started. ADMA5057E: Application validation failed with an unexpected exception while checking module to server relationship: org.eclipse.jst.j2ee.commonarchivecore.internal.exception.Deploy mentDescriptorLoadException: dd_in_ear_load_EXC_ ... ADMA5014E: The installation of application WebServer failed. Exception at the install !!!! Please contact IBM support ... WASX7309W: No "save" was performed before the script "E:\Program Files\IBM\TPC/web/scripts/deployWebServer.py" exited; configuration changes will not be saved. ... BPCIN0004E An error occurred during the installation of the Web-based GUI component.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Those installing TPC 5.2.x on Windows when TPC cd image * * download or extract was corrupted (extract corruption may be * * due to Anti-virus) so that <TPC_cdimage>\web\WebServer.ear * * does not contain a lib folder * * or TPC_cdimage>\web\WebServer.ear\lib exists, but it does * * not contain the file com.ibm.tivoli.rest.utils.jar. * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0007 - target August 2015 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
1) Ensure the option for full rollback is selected and click OK the error window in TPC installer and wait until it finishes. Then close it. Reboot the machine if the installer asks for it. 2) Run checksum on the media you have currently downloaded or download again the TPC zip parts and then compare their checksum values with the ones on the IBM website. You may have to specifically disable Anti-Virus or at least allow it to extract the TPC zip parts. E.g. for Windows, one checksum tool is the one from http://www.microsoft.com/en-us/download/details.aspx?id=11533 Provide back the checksum values for each package If that checks out.... 3) Verify that <TPC INSTALL MEDIA DIR>\web\WebServer.ear contains a lib folder which has more jar files, including i.e. com.ibm.tivoli.rest.utils.jar 4) Start the TPC installer, i.e. setup.bat from <TPC INSTALL MEDIA DIR>
Comments
APAR Information
APAR number
IT09276
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-08
Closed date
2015-06-29
Last modified date
2015-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INSTALL
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
Document Information
Modified date:
05 October 2023