IBM Support

IT08769: SKIPNTSECURITYCRC OPTION IS NOT HONORED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During an incremental backup, if a file is detected which has
    had it's  'File Security CRC' changed,  it is backed up,
    despite the fact that
    option SKIPNTSECURITYCRC=YES is used.
    
    Tivoli Storage Manager Versions Affected:  6.4 and 7.1  on
    Windows platforms
    
    Customer/L2 Diagnostics :
    
    Here is a service trace extract showing one attributes
    comparison example performed with the skipntsecuritycrc option
    set to yes, during an incremental backup
    At the end we see  "Comparison result = ATTRIBS_BACKUP" which
    is abnormal as only the 'File Security CRC' attribute changed.
    
    : fioCmpAttribs(): Entry.
    : ***** A t r i b  T r a c e *****
    : fioCmpAttribs(): ignoring attributes: '--N A -------- -- --
    --  (0x000000a0)'
    : fioCmpAttribs(): File Size unchanged since backup
    : fioCmpAttribs(): Compared FILETIME formated time stamps.
    : fioCmpAttribs(): File Date/Time unchanged since backup
    : fioCmpAttribs(): File Attributes unchanged since backup
    : fioCmpAttribs(): File MSDfs unchanged since backup
    : fioCmpAttribs(): File Security unchanged since backup
    : fioCmpAttribs(): File Share unchanged since backup
    : fioCmpAttribs(): File Security CRC changed since backup  <==
    : fioCmpAttribs(): Named Stream Size unchanged since backup
    : fioCmpAttribs(): Backup Stream Size unchanged since backup
    : fioCmpAttribs(): GPFS attributes unchanged since backup
    : fioCmpAttribs(): Hard Links Hash unchanged since backup
    fioCmpAttribs(): old attrib's data from build (IBM TSM 7.1.1.3)
    : ***** A t r i b  T r a c e  E n d *****
    : HSMWIN - fioCmpAttribs: no 'content change'
    : fioCmpAttribs(): returning ATTRIBS_BACKUP
     HSMWIN - psHSMWinCmpIncRecallCheck: backup type: 0
     HSMWIN - psHSMWinCmpIncRecallCheck: Comparison result =
    ATTRIBS_BACKUP
    
    
    
    
    Initial Impact: Medium
    
    Additional Keywords:  TSM INCREMENTAL UNNEEDED SKIPNTPERMISSION
    

Local fix

  • Use option SKIPNTPERMISSION=YES.
    This will allow an incremental backup to run without saving the
    file permissions at all, so it is to be used with care.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Tivoli Storage Manager Client versions 5.5, 6.1, 6.2, 6.3,   *
    * 6.4 and 7.1 on all Microsoft Windows platforms               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available. This problem is currently *
    * projected to be fixed in level 7.1.3.                        *
    * Note that until these levels are available, this information *
    * is subject to change at the discretion of IBM.               *
    ****************************************************************
    *
    

Problem conclusion

  • The problem has been fixed so that it no longer occurs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT08769

  • Reported component name

    TSM CLIENT

  • Reported component ID

    5698ISMCL

  • Reported release

    71W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-07

  • Closed date

    2015-05-21

  • Last modified date

    2015-05-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DSM      DSMC     DSMCAD   DSMCSVC
    

Fix information

  • Fixed component name

    TSM CLIENT

  • Fixed component ID

    5698ISMCL

Applicable component levels

  • R71W PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71W","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: