IBM Support

IT08682: FABRIC PROBE FAILS WITH DB2 SQL ERROR: SQLCODE=-811.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Fabric probes fail - The fabric probe logs will show:
    BTADS0035E The execution of the job failed with:
    cm.ibm.db2.jcc.am.SqlException:  DB2 SQL Error Error:
    SQLCODE=-811, SQLSTATE=21000, SQLERRMC=null, DRIVER=3.65.77
    This fixes the fabric probe code to better handle the scenario
    which causes this problem: two or more connections in the
    database for one proxy node port.
    RECREATE STEPS:
    Run TPC fabric probe against BNA CIMOM.  Observe described
    failure
    ________________________________________________________________
    DB2 Version used for Server:    N/A
    The defect is against component:   5508TPC00
    Server/Manager build/release (TPC):   5.2.5
    ___________________________________________________
    Problem as described by customer:   Brocade fabric probes fail
    with BPTDS0035E
    Initial customer impact (low/med/high): med
    

Local fix

  • apply fixing PTF when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC 5.2.x users with Brocade switches with IFR ports         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0007 - target August 2015
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT08682

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    525

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-01

  • Closed date

    2015-06-26

  • Last modified date

    2015-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABRIC
    

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

  • R520 PSY

       UP

  • R525 PSY

       UP

  • R526 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"525","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
22 February 2022