IBM Support

IT06760: DCX SWITCH VIA SNMP CONFIGURATION FAILS TO COLLECT PERFORMANCE DATA WITH TIMEOUTS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • tracePerfMgr.log.trace
    
    2015-01-20 18:07:31.079-0500  CollThread8
    FaMibTableAccessor validateMib
    DEBUG_MIN Unable to retrieve FE-MIB performance data for
    Device_Name (Device_Id). Trying other MIBs.
    com.ibm.tpc.perf.counter.DeviceOpFailedException: HWNPM4174E
    Performance data collection poll task timed out after 75 seconds
    for device: Device_Name (Device_Id).
    at
    com.ibm.tpc.perf.counter.MibTableAccessor.getOidResults(CounterD
    ataServiceSwitchSnmp.java:2492)
    at
    com.ibm.tpc.perf.counter.MibTableAccessor.getOidResult(CounterDa
    taServiceSwitchSnmp.java:2222)
     at
    com.ibm.tpc.perf.counter.MibTableAccessor.findAvailPorts(Counter
    DataServiceSwitchSnmp.java:1641)
     at
    com.ibm.tpc.perf.counter.MibTableAccessor.validateMib(CounterDat
    aServiceSwitchSnmp.java:1512)
    at
    com.ibm.tpc.perf.counter.CounterDataServiceSwitchSnmp.pollForCou
    nterData(CounterDataServiceSwitchSnmp.java:918)
    at
    com.ibm.tpc.perf.base.CollLogic.collectData(CollLogic.java:1592)
     at
    com.ibm.tpc.perf.base.CollLogic.performSamplePass(CollLogic.java
    :1419)
     at
    com.ibm.tpc.perf.base.CollectorThread.recoverableRun(CollectorTh
    read.java:1645)
     at com.ibm.tpc.perf.base.PmThread.run(PmThread.java:390)
    2015-01-20 18:07:31.079-0500 CollThread8
    FaMibTableAccessor validateMib
    EXIT return value =
    2015-01-20 18:07:31.079-0500 CollThread8
    FaMibTableAccessor retrievePortStats
    ENTRY
    2015-01-20 18:07:31.079-0500 CollThread8
    FaMibTableAccessor retrievePortStats
    EXIT return value = 0 stats objs.
    2015-01-20 18:07:31.079-0500 CollThread8
    CollectorThread processCollection
    ENTRY parm 1 = iNewRecCnt=0, tm=HWNPM2133W
    2015-01-20 18:07:31.079-0500 CollThread8
    CollectorThread processCollection
    DEBUG_MIN   Sample pass failed for device Device_Name
    (Device_Id) [device_IP].
    java.lang.NullPointerException
    at
    com.ibm.tpc.perf.counter.CounterDataServiceSwitchSnmp.pollForCou
    nterData(CounterDataServiceSwitchSnmp.java:998)
    at
    com.ibm.tpc.perf.base.CollLogic.collectData(CollLogic.java:1592)
    at
    com.ibm.tpc.perf.base.CollLogic.performSamplePass(CollLogic.java
    :1419)
    at
    com.ibm.tpc.perf.base.CollectorThread.recoverableRun(CollectorTh
    read.java:1645)
        at com.ibm.tpc.perf.base.PmThread.run(PmThread.java:390)
    2015-01-20 18:07:31.079-0500 CollThread8
    CollectorThread updateState
    ENTRY parm 1 = 4
    
    RECREATE STEPS: Configure Fabrics Switches to use SNMP
    connection vs. SMI-S
    ________________________________________________________________
    DB2 Version used for Server:  10.1.4
    The defect is against component:
    Server/Manager build/release (TPC):  5.2.3
    Agent build/release (TPC):  N/A
    Server/Manager (OS):  N/A
    Agent (OS):   N/A
    ________________________________________________________________
    Problem as described by customer: Unable to retrieve Performance
    Data from Switch using SNMP Config
    Initial customer impact (low/med/high):  med
    

Local fix

  • Engage Support
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC 5.2.2 through 5.2.5 users monitoring switch performance  *
    * data via SNMP                                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When using Brocade Switches with more than 200 ports,        *
    * performance monitoring fails.  See ERROR DESCRIPTION.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • Added a batch mechanism for data collection, so that the larger
    switches can be used for performance monitoring by collecting
    the data in smaller chunks.  The fix for this APAR is targeted
    for the following maintenance package:
    
    | refresh pack | 5.2-TIV-TPC-RP0006 - June 2015
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT06760

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    522

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-28

  • Closed date

    2015-02-10

  • Last modified date

    2015-02-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABRIC
    

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

  • R522 PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"522"}]

Document Information

Modified date:
22 February 2022