Direct links to fixes
Tivoli Storage Productivity Center Refresh Pack 5
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
TPC probe jobs fail when there is no HBA in the storage subsystem. In the tracePerfMgr.log: ======================== 2014-10-29 09:07:00.212+0100 CollThread14 ConfigDataServiceTpc getPortConfig ENTRY parm 1 = DeviceId=DeviceId@407dc (Snap=1008, Type=4, Key=2012, Name=000000C123456789, Nick=Storwize V3700-2072-XXXXXXXXXXX-IBM) 2014-10-29 09:07:00.228+0100 CollThread14 ConfigDataServiceTpc getPortConfig EXIT return value = 0 Ports. 2014-10-29 09:07:00.290+0100 CollThread14 CollLogicSvc updateConfigData DEBUG_MIN Unable to retrieve subsystem port configuration data for Storwize V3700-2072-XXXXXXXXXXX-IBM (000000C123456789). 2014-10-29 09:07:00.290+0100 CollThread14 CollectorThread activateCollection DEBUG_MIN Unable to retrieve config data for Storwize V3700-2072-XXXXXXXXXXX-IBM (000000C123456789). com.ibm.tpc.common.api.TPCServerException: HWNPM2050E Failed to get the latest configuration data for device Storwize V3700-2072-XXXXXXXXXXX-IBM (000000C123456789). at com.ibm.tpc.perf.base.CollLogicSvc.updateConfigData(CollLogicSvc .java:378) at com.ibm.tpc.perf.base.CollectorThread.activateCollection(Collect orThread.java:2093) at com.ibm.tpc.perf.base.CollectorThread.recoverableRun(CollectorTh read.java:1467) at com.ibm.tpc.perf.base.PmThread.run(PmThread.java:390) 2014-10-29 09:07:00.290+0100 CollThread14 CollectorThread deactivate DEBUG_MIN Ending monitor for Storwize V3700-2072-XXXXXXXXXXX-IBM (000000C123456789), reason: monitor startup failed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.x users running performance monitor on SVC and * * Storwize that do not have FC Ports but only iSCSI ports * **************************************************************** * PROBLEM DESCRIPTION: * * Performance monitor fails for SVC or Storwize subsystems * * that do not have FC ports with errors: * * HWNPM2111E The performance monitor for device <Device_name> * * failed because of errors retrieving the latest configuration * * data for the device. * * * * CollLogicSvc updateConfigData * * DEBUG_MIN Unable to retrieve subsystem port configuration * * data for <Device_Name>. * * CollThread14 CollectorThread * * activateCollection DEBUG_MIN Unable to * * retrieve config data for <Device_Name>. * * com.ibm.tpc.common.api.TPCServerException: HWNPM2050E * * Failed to get the latest configuration data for device * * <Device_Name>. * * at * * com.ibm.tpc.perf.base.CollLogicSvc.updateConfigData(CollLogi * * cSvc.java:378) * * at * * com.ibm.tpc.perf.base.CollectorThread.activateCollection(Col * * lectorThread.java:2093) * * at * * com.ibm.tpc.perf.base.CollectorThread.recoverableRun(Collect * * orThread.java:1467) * * at com.ibm.tpc.perf.base.PmThread.run(PmThread.java:390) * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0005 - target March 2015 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT05263
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
523
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-11-03
Closed date
2014-11-05
Last modified date
2014-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DISK
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
Document Information
Modified date:
05 October 2023