Direct links to fixes
Tivoli Storage Productivity Center Refresh Pack 4
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
RECREATE: 1. I have three Cisco switches added to my TPC Server managed through SNMP-only. All three of these are connected in the same physical fabric. 2. I ran several probes throughout the day with everything running fine. 3. At some point, one of the switches must have been too slow to respond to SNMP queries, because this switch went unreachable on one of the probes. I saw this in the logs: 2014-10-23 05:19:37.374-0700 Agent <switch_IP>is not responding to FC MGMT MIB queries after 1 attempts. com.ibm.tpc.discovery.snmp.scanner.TopologyScanner getWWN with parms Process Processor (Thread-101) 4. All Probes after this leave the switch in the unreachable state, even though in the Java legacy UI the SNMP Data Source status for this switch is Normal.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.x users with SNMP data sources for switches * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0004 - target November 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT05159
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
523
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-10-24
Closed date
2014-10-31
Last modified date
2014-10-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
R521 PSY
UP
R522 PSY
UP
R523 PSY
UP
Document Information
Modified date:
22 February 2022