Direct links to fixes
Tivoli Storage Productivity Center Refresh Pack 4
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
In the TPC installer log on Windows shows following error: Execute failed: java.io.IOException: Cannot run program "\bin\trcmd.bat" On Linux/AIX it shows: The directory /cognos/bin does not exist When trying to install TPC reports, at TPC preinstall, if the error: "BPCIN0238E The Tivoli Common Reporting server located at C:\Program Files\IBM\JazzSM\reporting cannot be reached." occurs for some reason and the user clicks then the previous button on "Configure Jazz for Service Management and Tivoli Common Reporting" panel, fixes the problem in Tivoli Common Reporting and resumes the TPC installation by clicking Next on the "Choose Installation Location and Type" panel, the installer may fail at installation of TPC reports with "BPCIN0004E An error occurred during the installation of the Tivoli Storage Productivity Center reports component."
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Those installing TPC 5.2.x in a single server install * * scenario when TPC reports are installed later, as the * * remaining TPC component to be installed. * * The issue happens only if there are JazzSM validation errors * * on the "Configure Jazz for Service Management and Tivoli * * Common Reporting" panel * * and the user clicks then Previous button and then from * * "Choose Installation Location and Type" panel clicks Next * * and then Install. * **************************************************************** * PROBLEM DESCRIPTION: * * Installation of TPC reports fail with "BPCIN0004E An error * * occurred during the installation of the Tivoli Storage * * Productivity Center reports component." * * In the TPC installer log: * * on Windows there is an error like this: Execute failed: * * java.io.IOException: Cannot run program "\bin\trcmd.bat" * * on Linux/AIX there is an error like this: The directory * * /cognos/bin does not exist * * * * When trying to install TPC reports, * * at TPC preinstall, if the error "BPCIN0238E The Tivoli * * Common Reporting server located at C:\Program * * Files\IBM\JazzSM\reporting cannot be reached." * * occurs for some reason and the user clicks then Previous * * button on "Configure Jazz for Service Management and Tivoli * * Common Reporting" panel, * * fixes the problem in Tivoli Common Reporting and resumes the * * TPC installation by clicking Next on the "Choose * * Installation Location and Type" panel, * * the installer may fail at installation of TPC reports with * * "BPCIN0004E An error occurred during the installation of the * * Tivoli Storage Productivity Center reports component." * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance packages: | refresh pack | 5.2-TIV-TPC-RP0004 - target TBD The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
A temporary fix includes some manual changes to <TPC_INSTALL_DIR>/config/InstallVariable.properties. Because this is a TPC internal configuration file, caution should be exercised and changing that file. It's recommended to ask L2/L3 support to provide an action plan after the TPC logs are collected using the TPC service tool. An example of such an action plan for Windows is the following: 1) click the OK button in the TPC installer and wait until installer finishes, then close it. 2) edit C:\Program Files\IBM\TPC\config\InstallVariable.properties and replace: varTCRHostName= with varTCRHostName=<real_host_name_here> varTCRPort= with varTCRPort=16311 TCR_INSTALL_DIR= with TCR_INSTALL_DIR=C\:\\Program Files\\IBM\\JazzSM\\reporting varJazzSMUsrPW= with varJazzSMUsrPW=<here_the_encrypted_form_with_escaped_equal_sign_ see_comment_above_about_tpctool_encrypt> Please note that <here_the_encrypted_form_with_escaped_equal_sign_see_comment_abo ve_about_tpctool_encrypt> must be replaced according to the details from below: varJazzSMUsrPW must be saved in encrypted form (encryption can be done using C:\Program Files\IBM\TPC\cli\tpctool.bat encrypt <jazzSM_password_in_clear_here>). Also, any = sign in the encrypted form must be escaped with a \, e.g. for an encrypted password value of LZFV7KXFluECfjcxoDXzQg== the escaped value in InstallVariable.properties will be LZFV7KXFluECfjcxoDXzQg\=\= Then save the changes made to InstallVariable.properties 3) start again the TPC installer to install the TPC reports.
Comments
APAR Information
APAR number
IT03408
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-30
Closed date
2014-08-11
Last modified date
2014-08-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INSTALL
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R521 PSY
UP
Document Information
Modified date:
23 March 2022