Fixes are available
APAR status
Closed as program error.
Error description
When IPv6 SLAAC is used to provision redundant routers in a DataPower appliance, if the currently preferred router fails, the DataPower appliance will not switch to the backup router until the provisioned route lifetime expires. The DataPower appliance is not failing over to the backup router when the preferred router fails neighbor discovery and is removed from neighbor cache. The fail over does occur when the preferred route's lifetime, as set During SLAAC provisioning, is reached.
Local fix
Wait for the route lifetime to expire.
Problem summary
Affected is DataPower appliance in IPv6 networks using RFC-2461 Router Advertisement (RA) messages. In some cases, when the preferred router becomes unreachable, the firmware does not switch to the backup router, causing a temporary loss of connectivity. This recovers after the timeout in RA message expires.
Problem conclusion
Fix is available in 7.0.0.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT03080
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-14
Closed date
2014-09-19
Last modified date
2014-09-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R700 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]