IBM Support

IT03029: BAD INDEX ON HDR SECONDARY IN A COMBINED ER PRIMARY TARGET SYSTEM WITH ATTACHED HDR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • In a combined ER primary target with an attached HDR secondary
    on the ER target occasionally
    assert fails with "Error during recovery left index
    inconsistent" messages. Afterward the indicated
    index is bad on the HDR secondary. On the HDR primary and the ER
    primary no errors occur.
    
    Message looks like this :
    
    03:17:30  Assert Warning: Error during recovery left index
    inconsistent.
    03:17:30  IBM Informix Dynamic Server Version 12.10.FC1
    03:17:30   Who: Session(19, informix@server, 0, 0x4b90e268)
                    Thread(37, xchg_1.1, 4b8d1da8, 12)
                    File: rskey.c Line: 1647
    03:17:30   Results: Index
    'test:"informix".ta_kmo_zu_ne#ux_kmozune_une' is now unusable
    03:17:30   Action: Run 'oncheck -cI
    test:"informix".ta_kmo_zu_ne#ux_kmozune_une'
    03:17:30  stack trace for pid 25333 written to
    /work/1210/tmp/af.40d46aa
    03:17:30   See Also: /work/1210/tmp/af.40d46aa
    03:17:31  Error during recovery left index inconsistent.
    03:17:31  Rollforward of log record failed. iserrno = 100
    03:17:31  Log Record: log = 18, pos = 0x9d9684, type =
    OLDRSAM:ADDITEM(28), trans = 3691395284195082276
    03:17:31  Rollforward of log record failed. iserrno = 100
    03:17:31  Log Record: log = 18, pos = 0x9d9684, type =
    OLDRSAM:ADDITEM(28), trans = 36
    
    
    03:17:30  doadditem: Node 0x1, match 3
    03:17:30  Could not add item, rowid 0x104, key:
    KEY:4961:"NE5":
    03:17:30  Node
    Node 1 Root+Leaf Prev 0 Next 0
    page 1:69227 sz 2048 flags b0 nslots 3 frcnt 1969 frptr 401 next
    0 prev 0
    Slot 1 sl_ptr 388 sl_len 13 sl_flags 0
    :4961:"NE3":
            10028d   103
    Slot 2 sl_ptr 375 sl_len 13 sl_flags 0
    :4961:"NE4":
            10028d   102
    Slot 3 sl_ptr 362 sl_len 13 sl_flags 0
    :4961:"NE5":
            10028d   101
    ----------------------------------------------------------------
    ------
    03:17:30
    03:17:30  IBM Informix Dynamic Server Version 12.10.FC1 Software
    Serial Number AAA#B000000
    
    03:17:30  Assert Warning: Error during recovery left index
    inconsistent.
    03:17:30   Who: Session(19, informix@coelho, 0, 0x4b90e268)
                    Thread(37, xchg_1.1, 4b8d1da8, 12)
                    File: rskey.c Line: 1647
    03:17:30   Results: Index
    'test:"informix".ta_kmo_zu_ne#ux_kmozune_une' is now unusable
    03:17:30   Action: Run 'oncheck -cI
    test:"informix".ta_kmo_zu_ne#ux_kmozune_une'
    03:17:30  Raw hex dump of stack located in
    /work/1210/tmp/af.40d46aa.rawstk
    03:17:30  Stack for thread: 37 xchg_1.1
    
    (oninit) afstack
    (oninit) afhandler
    (oninit) afwarn_interface
    (oninit) kybad
    (oninit) plogredo
    (oninit) rlogm_redo
    (oninit) next_recvr
    (oninit) producer_thread
    (oninit) startup
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IDS-12.10.xC5                                      *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IDS-12.10.xC5
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT03029

  • Reported component name

    IFMX ULT WHSE E

  • Reported component ID

    IM0019BOS

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-07-08

  • Closed date

    2015-10-16

  • Last modified date

    2015-10-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IFMX ULT WHSE E

  • Fixed component ID

    IM0019BOS

Applicable component levels

  • RB70 PSN

       UP

  • RB70 PSY

       UP

  • RC10 PSN

       UP

  • RC10 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSBJS3","label":"Informix Ultimate Warehouse Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]