Error description

  • Personal Communications, Version 6.0.9 and 6.0.10
    ------------------------------------------------
    LUA application hangs when the link is stopped (or fails) and is
    restarted, because the RUI_INIT verb does not return.
    ------------------------------------------------
    See original CS/Win APAR JR27955 for more information
    

Local fix

  • Stop the application before restarting the link.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of LUA applications                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Trace shows:                                                 *
    * RUI_INIT -->                                                 *
    *            (link activation)                                 *
    *            <-- ACTLU RQ                                      *
    *            NOTIFY RQ (SLU enable)->                          *
    *            ACTLU +RSP                                        *
    *            <-- NOTIFY -RSP 80050000                          *
    * <-- RUI_INIT SESSION_FAILURE                                 *
    *              LU_COMPONENT_DISCONNECTED                       *
    * RUI_INIT -->                                                 *
    * The new RUI_INIT never returns.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The host correctly rejected the NOTIFY with sense code
    8005000 "No Session", since it had not received the ACTLU RSP
    first. It then processed the ACTLU +RSP and believes the
    SSCP-LU half-session is available for use. When PCOM
    received the 80050000 sense code, it marked the LU as inactive
    internally. This caused the RUI_INIT failure. The subsequent
    RUI_INIT will hang pending activation of the LU, which is
    assumed to be possible because the link is active, or until
    the link terminates. However, this will not happen in this
    case, because the host thinks the LU is active, and PCOM
    thinks it is inactive and cannot do anything to request
    activation.
    .
    The cause of this problem is that the NOTIFY RQ was
    transmitted before the ACTLU +RSP. Additional examination
    revealed a severe level of network-level retransmissions due
    to an external network issue. In PCOM, the ACTLU RSP and the
    NOTIFY RQ are processed by two different queues, and the
    pressure caused by the retransmissions caused the queue
    processing the ACTLU RSP to be slightly delayed relative to
    the NOTIFY RQ.
    

Problem conclusion

  • APPN.SYS code has been modified to ensure that the ACTLU RSP is
    transmitted before the NOTIFY RQ.
    
    Fix scheduled for PCOM 6.0.11 Refresh Pack
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT02277

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I7000

  • Reported release

    609

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-05

  • Closed date

    2014-06-06

  • Last modified date

    2014-08-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IT03881 IT03882 IT03883

Modules/Macros

  • APPN     LLC2
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R609 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"609","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
20 August 2014