Direct links to fixes
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if010
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if015
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if017
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if022
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.6.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
4.6.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006-if018
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
Several inconsistencies around specifying a checkpoint interval value in initialization parameters or in CD Requester, like - When the user sets a new value, it is not always validated and converted correctly. - When resetting the value, the default is 64 K instead of 10 M as documented. - Initialization parameters do not display the value as M when possible. - Edit control in CD Requester is too small and only allows the user to for 3-digits.
Local fix
STRRTC - 414380 VF / SF Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.5.00 Sterling Connect:Direct for Windows 4.5.01 Sterling Connect:Direct for Windows 4.6.0 Problem Description: Several inconsistencies around specifying a checkpoint interval value in initialization parameters or in CD Requester. For example, initialization parameters do not display the value as M when possible. When the user sets a new value, it is not always validated and converted correctly. When resetting the value, a default of 64 K is applied instead of 10 M as documented. Edit control in CD Requester is too small and only allows the user to enter 3-digits. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Updated validation routines to use a consistent upper limit of 2047 megabytes (M) or 2097151 kilobytes (K) for the checkpoint interval. Fixed the default to be 10 M. Fixed KM-to-bytes conversion routines to check for overflow and fail. Updated the Edit Control in the COPY statement UI in CD Requester allowing the user to enter up to 7 digits. Delivered In: Sterling Connect:Direct for Windows 4.5.00 Build 051 Fix 97 Sterling Connect:Direct for Windows 4.5.01 Build 017 Fix 63 Sterling Connect:Direct for Windows 4.6.0.3_iFix018
Temporary fix
Comments
APAR Information
APAR number
IT00339
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
460
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-03-14
Closed date
2014-03-20
Last modified date
2014-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
25 August 2023