Error description

  • Problem Description - Customer has some AIX systems where the
    HACMP sensor failed by getting information about applications
    associated with HACMP Resource Groups.
    
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    session.SshSessionClient - Command stdout:
    
    SESCM_AC:/etc/cluster/scripts/SESCM/SESCMDB_start.sh:/etc/cluste
    r/scripts/SESCM/SESCMDB_stop.sh:background:
    
    SES_AC:/etc/cluster/scripts/SES/SES_start.sh:/etc/cluster/script
    s/SES/SES_stop.sh:background:
    
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    session.SshSessionClient - Spent 0.219 seconds in executeCommand
    
    
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    parsers.HACMPGenericParser - Unable to parse local apps, missing
    crucial data
    
    TADDM sensor tried to split line
    SESCM_AC:/etc/cluster/scripts/SESCM/SESCMDB_start.sh:/etc/cluste
    r/scripts/SESCM/SESCMDB_stop.sh:background:
    
    
    Using ?:? but expects 3 items but got more (4,5) (probably
    because of new version of HACMP) Java class related to problem
    HACMPAppResourceParser.class
    
    
    
    
    
    So code change made to handle the output of ?cllsserv -c?
    command even if there are more columns than 3.
    

Local fix

  • n/a
    

Problem summary

  • Customer has some AIX systems where the
    HACMP sensor failed while getting information about applications
    associated with HACMP Resource Groups with the following log
    messages:
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    session.SshSessionClient - Command stdout:
    SESCM_AC:/etc/cluster/scripts/SESCM/SESCMDB_start.sh:/etc/cluste
    r/scripts/SESCM/SESCMDB_stop.sh:background:
    SES_AC:/etc/cluster/scripts/SES/SES_start.sh:/etc/cluster/script
    s/SES/SES_stop.sh:background:
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    session.SshSessionClient - Spent 0.219 seconds in executeCommand
    2019-05-21 17:25:41,529 DiscoverManager [DiscoverWorker-5]
    2019052117250279#HACMPSensor-X.X.X.X DEBUG
    parsers.HACMPGenericParser - Unable to parse local apps, missing
    crucial data
    TADDM sensor tried to split line
    SESCM_AC:/etc/cluster/scripts/SESCM/SESCMDB_start.sh:/etc/cluste
    r/scripts/SESCM/SESCMDB_stop.sh:background:
    using : but expects 3 items. However,  on receipt of more than
    3 items, this issue occurs.
    This APAR handles the output of cllsserv -c
    command even if there are more than 3 columns.
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages:
    | Fix Pack | 7.3.0-TIV-ITADDM-FP0007
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ16930

  • Reported component name

    APP DEPENDENCY

  • Reported component ID

    5724N5500

  • Reported release

    730

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-06-18

  • Closed date

    2019-07-05

  • Last modified date

    2019-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    APP DEPENDENCY

  • Fixed component ID

    5724N5500

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"730","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]