IJ12656: EIF EVENT SLOTS MISSING OR MIS-NAMED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:   ITM agent
    Version: 6.3.0 FP3 - FP7
    
    Background: EIF events contain slots with names and values.
    Some slots contain agent-neutral information about the
    event--these slots have reserved names that are common across
    all events. The other slots contain data from attributes in the
    attribute group row that caused the event to be
    generated--these slots have names that are the similar to the
    attribute names. If an attribute has the same name as a
    reserved slot, then the corresponding slot name should be
    formed by joining the agent product code, an underscore, and
    the attribute name.
    
    Problem Description: EIF event slots that correspond to
    attributes whose name is the same as a reserved slot are no
    longer added to the event, or in some cases are added to the
    event but without adding the product code to the slot name.
    
    Detailed Recreation Procedure: In ITM 6.3.0 FP7, create a
    private situation whose condition will evaluate to true on at
    least one row on an attribute group containing an attribute
    with one of these reserved slot names (without respect to
    case): acl, adapter_host, administrator, appl_label,
    cause_date_reception, cause_event_handle, class, cms_hostname,
    cms_port, collection, credibility, date, date_reception,
    dispatcher, distrib_admin, duration, effective_value,
    event_handle, fqhostname, hostname, info, integration_type,
    master_reset_flag, monitor, msg, msg_catalog, msg_index,
    num_actions, origin, probe, probe_arg, prev_value, relation,
    relation_delta, repeat_count, response_level, server_handle,
    server_path, severity, situation_displayitem,
    situation_eventdata, situation_fullname, situation_group,
    situation_name, situation_origin, situation_status,
    situation_time, source, status, sub_source, sub_origin, tmr,
    ttid, units, value. The resulting EIF event will not contain a
    slot with a name in the form kpc_attributename.
    
    Related Files and Output:
    Messages found in logs etc
    No error messages, just missing or mis-named slots
    

Local fix

Problem summary

  • EIF events contain slots with names and values.  Some slots
    contain agent-neutral information about the event--these slots
    have reserved names that are common across all events.  The
    other slots contain data from attributes in the attribute group
    row that caused the event to be generated--these slots have
    names that are the similar to the attribute names.  If an
    attribute has the same name as a reserved slot, then the
    corresponding slot name should be formed by joining the agent
    product code, an underscore, and the attribute name.
    
    
    EIF event slots that correspond to attributes whose name is the
    same as a reserved slot are no longer added to the event, or in
    some cases are added to the event but without adding the product
    code to the slot name.
    

Problem conclusion

  • Modify the processing to join the agent product code together
    with an underscore character (_) followed by the attribute name
    for attributes that have the same name as the reserved slot.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | service pack | 6.3.0.7-TIV-ITM-SP0001
       | interim fix  | 6.3.0.7-TIV-ITM_TEMA-IF0008
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ12656

  • Reported component name

    TEMA

  • Reported component ID

    5724C04TE

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-01-10

  • Closed date

    2019-05-06

  • Last modified date

    2019-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TEMA

  • Fixed component ID

    5724C04TE

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: