Direct links to fixes
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if010
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if015
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if017
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if022
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
Error description: By default, the IBM solidDB database is installed with a maximum database size of 2000M. This can be too limiting on some very busy nodes when the user has significantly increased stat.max.age to keep a large history of statistics.
Local fix
STRRTC - 39851 MM/MM Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.6.0.1 or later using IBM solidDB Problem Description: Allow the IBM solidDB database to grow larger than 2000M. This might be useful on some very busy nodes when the user has significantly increased stat.max.age to keep a large history of statistics. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Increased the default maximum database size to 8000M in new installers. To increase the maximum database size for an existing installation, follow the steps described in the Tempory Fix section. Delivered In: Sterling Connect:Direct for Windows 4.6.0.3_iFix012
Temporary fix
To increase the maximum database size for an existing installation, follow these steps: (1) Stop the IBM solidDB - Connect Direct v4.6.00 service. (2) Edit the solid.ini file located in your Connect Direct v4.6.00\solidDB6.5\cdwinnt folder and update the FileSpec_1 parameter, like: FileSpec_1=solid.db 8000M (3) Start the IBM solidDB - Connect Direct v4.6.00 service again.
Comments
APAR Information
APAR number
IC97952
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
460
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-11-26
Closed date
2013-11-26
Last modified date
2013-11-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
25 August 2023