IC97609: 3270 BIDI SCREEN BLINKING NOT BEHAVING PROPERLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • On one of the customer 3270 appliation screens that contained
    a BLINKING TEXT FIELD is not behaving properly.
    The blinking field behalves well only if flipping the 3270
    screen from Left to Right, but in the case where the screen is
    flipped Right to Left then the whole line which contained this
    field blinks. Only the field should blink.
    When flipping back to Left to Right then only the fiels that is
    suppose to blink blinks.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Host On-Demand BIDI users                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When Right to Left (RTL) is selected    *
    *                      on the screen, the entire line blinks   *
    *                      rather than just the field that         *
    *                      should blink.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    For each blink of each blinking field, "Update PS" event is
    generated. It contains information about boundaries of blinking
    text, and the text is taken from TextPlane. However these
    boundaries are calculated incorrectly in RTL screen.
    As result, either nothing blinks or the entire line blinks.
    

Problem conclusion

  • Coordinate calculation fixed in (RTL) Right to Left screen
    columns are counted from right to left.
    
    Fix scheduled for HOD 11.0.9 Refresh Pack
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC97609

  • Reported component name

    HOD

  • Reported component ID

    5733A5901

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-11-12

  • Closed date

    2013-11-15

  • Last modified date

    2013-11-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HOD_BIDI
    

Fix information

  • Fixed component name

    HOD

  • Fixed component ID

    5733A5901

Applicable component levels

  • RB00 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSS9FA","label":"IBM Host On-Demand"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 November 2013