IBM Support

IC97401: WTX MAP FAILS WHEN A LONG URL STRING IS USED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In firmware version 5.0.0.0 and later, binary transforms with
    WTX maps that use a URL string longer than 32 characters might
    result in the following error message:
    
    mpgw (MY_MPGW_Service): request My_policy_rule #1 xformbin:
    'Transforming (possibly binary) PIPE with
    var://context/mycontextvariable results stored in PIPE' failed:
    10: Internal error. Unexpected mapping error.
    

Local fix

  • Use a URL string less than 32 characters to work around this
    issue, as this failure is related to the length of the URL
    string.
    

Problem summary

  • Affected are customers who use WTX maps in DataPower.
    
    If the map name is longer than 32 bytes, processing might fail.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC97401

  • Reported component name

    DTPWR INTGRAPL

  • Reported component ID

    DP905XI52

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-11-04

  • Closed date

    2014-01-13

  • Last modified date

    2014-03-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DTPWR INTGRAPL

  • Fixed component ID

    DP905XI52

Applicable component levels

  • R500 PSY

       UP

  • R600 PSY

       UP

  • R601 PSY

       UP