IBM Support

IC96828: INTERCHANGECONTROLNUMBER TAG IN PROCESS DATA IS INCORRECT WHEN OUTBOUND ENVELOPE USES "LIMIT INTERCHANGE SIZE" OPTION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When an outbound envelope uses the "maximum number of
    documents per interchange" or "limit interchange size" option
    to create multiple interchanges, then uses the option to
    "invoke business process for each interchange,"
    this tag in the invoked process contains the wrong interchange
    number:
      <InterchangeControlNumber>3</InterchangeControlNumber>
    
    The interchange number in that tag is the last interchange
    number generated and not the correct number for the interchange
    in the invoked process.
    

Local fix

  • No workaround available
    STRRTC 396092
    AE/AE
    

Problem summary

  • Users Affected:
    All users who are invoking a BP per interchange
    on outbound enveloping, with multiple interchanges.
    Problem Description:
    When an outbound envelope creates multiple interchanges and then
    uses the option to "invoke business process for each
    interchange," process data for the invoked process contains the
    wrong interchange control number.
    Platforms Affected:
    ALL
    

Problem conclusion

  • Resolution Summary:
    A fix has been provided that obtains the Control number from the
    info array of interchanges processed rather than from the static
    variable, which only contains the last control number processed.
    Delivered In:
    5020500_8
    5020600
    

Temporary fix

  • _5020402_71118646706_BRANCH
    _5050401_54297_BRANCH
    

Comments

APAR Information

  • APAR number

    IC96828

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    524

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-10-11

  • Closed date

    2013-10-16

  • Last modified date

    2015-10-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
24 August 2023