Fixes are available
APAR status
Closed as program error.
Error description
Windows XP Pcomm6.0 CSD#5 OS/400 V7R1 This customer has configured the Enterprise Extender connection. When they push the button of the data transmission "to the host", the data transmission protocol in the generated window will choose TCPIP by default. In the case of "from the host", SNA was selected by default. They think SNA should be chosen for both.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Data Transfer utility users with SNA * * host connectivity * **************************************************************** * PROBLEM DESCRIPTION: Incorrect transfer protocol is pre- * * selected when user opens the Data * * Transfer utility from a SNA emulator * * session. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a user opens the Data Transfer utility (also called iSeries-PC Transfer Utility) to upload files to a 5250 host from a emulator session that is connected using SNA, the incorrect protocol is selected by default. The selection of the protocol should be based on the active connection with the host (TCP/IP or SNA).
Problem conclusion
PCSAFT.DLL has been changed to detect the active connection protocol when the user starts the Data Transfer utility from the emulator session so the correct transfer protocol is pre- selected in the utility. Fix scheduled for PCOM 6.0.9 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC96019
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-17
Closed date
2013-09-27
Last modified date
2013-09-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSAFT
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R601 PSY
UP