Fixes are available
APAR status
Closed as program error.
Error description
Using WTX maps with tracing enabled, might create a trace file, trace_xdsmtr.xml, in the encrypted area of the DataPower file system that might use all available space. The file can only be deleted by a tool supplied by IBM DataPower support.
Local fix
Disable tracing using WebSphere Transformation Extender Design Studio.
Problem summary
Customers using binary transforms, with dpa maps that have trace enabled, might generate unwanted trace files in the internal flash drive, which will eventually take up the all the space.
Problem conclusion
Fix is available in 5.0.0.11 and 6.0.0.3. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC95913
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-12
Closed date
2013-10-23
Last modified date
2013-11-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R500 PSN
UP
R600 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]