Fixes are available
APAR status
Closed as program error.
Error description
DataPower might send errors to the client when a Web Service Proxy is configured with one-way operations. This might result in the client receiving an unexpected response.
Local fix
Chain all requests to the Web Service Proxy through a MPGW: - with pass-thru request type - with static backend http://127.0.0.1:xxxx (the port of the WSP) - with propagate URI on (this is dedault) - with SOAP response type - with Server-to-Client rule: match(uri=*) NULL--RESULT--OUTPUT Sending requests through this MPGW will eliminate any response received from Web Service Proxy, such as an error message response.
Problem summary
Affected is the use of a Web Service Proxy or Multi-Protocol Gateway in one-way mode. If an error occurs processing a request, the error response might be incorrectly sent to the client. Please note that DataPower implementation of one-way (for complete MPGW, the one-way operations of a WSP) is to make response pass-through. This has three consequences: 1) A configured response rule will not get executed in case of one-way processing 2) If a backend (incorrectly) returns "something" that will just be returned by DataPower as well (because of pass-through). The backend needs to be fixed to not break the one-way contract. 3) For HTTP protocol, the HTTP response body will be empty, but the HTTP response headers will be returned to client (allowing to access eg. HTTP response code).
Problem conclusion
Fix is available in 5.0.0.10 and 6.0.0.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC92808
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-04
Closed date
2013-08-27
Last modified date
2013-09-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: