IC91024: FABRIC DEVICES WITH NO ASSOCIATED DATA SOURCE ARE NOT REMOVABLE FROM THE GUI.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Switches and Fabrics are detected via CIMOM and/or SRA data
    sources (when SRAs have the Fabric function enabled).  SRAs are
    capable of detecting all fabric-connected devices regardless of
    whether or not TPC supports the device.  When a user removes a
    data source that is managing a certain switch from TPC, all
    associated entities for that data source should be set to
    missing regardless of whether or not the device is supported.
    Unsupported devices appear in the topology viewer identified by
    WWN but may not have much other detail available.  These
    unsupported devices become orphaned when their managing data
    source is removed from TPC, and as such their detectability
    status never gets updated so they are not removable through the
    TPC GUI.
    With this APAR it will be assured that we check if the removed
    data source is the last one that is seeing a switch. If that's
    the case all related entities will be set to missing.
    RECREATE STEPS:
    Rare scenario.
    ________________________________________________________________
    DB2 Version used for Server:    N/A
    The defect is against component:   5608TPCS0
    Server/Manager build/release (TPC):   4.2.2
    Agent build/release (TPC):    N/A
    Server/Manager (OS):     N/A
    Agent (OS):       N/A
    ________________________________________________________________
    Problem as described by customer:   Unable to remove switch from
    TPC
    Initial customer impact (low/med/high): Med.
    

Local fix

  • Manual database alteration is required without the fix for this
    APAR being present.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: TPC 4.2.x and 5.1.x users monitoring         *
    *                 fabrics.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: There could be situations, where if     *
    *                      you disable the Fabric on the SRA and   *
    *                      the SRA is the last Data Source for a   *
    *                      Fabric, when running probe, the         *
    *                      corresponding switches remain online.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    -
    

Problem conclusion

  • The fix for this APAR is targeted for the following
    maintenance package:
    
    | fix pack | 4.2.2-TIV-TPC-FP0004 - target June 2013
    | fix pack | 5.1.1-TIV-TPC-FP0002 - target September 2013
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future fix packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC91024

  • Reported component name

    TPC STANDARD ED

  • Reported component ID

    5608TPCS0

  • Reported release

    422

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-21

  • Closed date

    2013-03-26

  • Last modified date

    2013-03-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IC95041

Fix information

  • Fixed component name

    TPC STANDARD ED

  • Fixed component ID

    5608TPCS0

Applicable component levels

  • R422 PSY

       UP