IBM Support

IC90393: INCORRECT FABRIC PROBE HANDLING FOR BROCADE SWITCHES WITH WWNS THAT CONTAIN THE OUI VALUE OF '0027F8'

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Brocade has added a new OUI value which is not recognized by
    TPC.  Because of this information for these switches and their
    fabrics is not collected as expected resulting in functional
    limitations.  This problem may be encountered with TPC or IBM
    System Director and VMcontrol.  Here are some sample errors that
    can be seen with TPC or VMcontrol.  These errors occur when
    there is a Brocade CIMOM agent already configured and monitoring
    the switches.
    The following samples of messaging may be found in the IBM
    System Director (VMcontrol) error-log-0.html:
    INFO Unable to start zoning transaction for fabricID:
    10000027F8xxxxxx
    com.ibm.tpc.common.api.TPCServerException: BTAFM4501E No agent
    is available to configure the zoning on the fabric with ID
    10000027F8xxxxxx
    Failed to start transaction on fabric 10000027F8xxxxxx. Check
    connection to switch(es)
    The following error shows up in TPC msgTPCDeviceServer.log:
    BTAFM4501E No agent is available to configure the zoning on the
    fabric with ID 10000027F806DA78.
    com.ibm.tpc.fabric.FabricManagerService startTransaction
    In the TPC GUI, you may experience unexpected messages in the
    probe logs indicating that the fabrics have limitations or you
    may not be able to get to the zone configuration panels due to a
    message stating no agent available, even when a CIMOM agent
    exists.
    Initial customer impact (low/med/high):  Med
    

Local fix

  • Log into server with db2admin or db2inst1 (or equivalent,
    depending on platform)
    connect to TPCDB
    db2 connect to TPCDB
    db2 set schema tpc
    db2 "insert into T_RES_OUI values ('0027F8','Brocade')"
    Initiate Fabric discovery in TPC or (VMcontrol Farm and Switch
    inventory)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: TPC 4.2.2.143 (FP3) and earlier or 5.1.1.0   *
    * and earlier users                                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: If you have a Brocade switch with the   *
    *                      value of "0027F8" in the middle of      *
    *                      the WWN, fabric probe will not          *
    *                      recognize it as a Brocade and           *
    *                      information about the switch and        *
    *                      fabric will not be collected as         *
    *                      expected.  Performance monitoring       *
    *                      functionality is not available for      *
    *                      for these switches.  This is most       *
    *                      likely to affect newer Brocade switches.*
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    -
    

Problem conclusion

  • The new OUI value of "0027F8" has been added to TPC with an
    association with Brocade for proper handling.
    
    The fix for this APAR is available in the following
    maintenance packages:
    
    | fix pack | 4.2.2-TIV-TPC-FP0004 - June 2013
    | fix pack | 5.1.1-TIV-TPC-FP0001 - April 2013
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future fix packs do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC90393

  • Reported component name

    TPC STANDARD ED

  • Reported component ID

    5608TPCS0

  • Reported release

    422

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-21

  • Closed date

    2013-02-23

  • Last modified date

    2013-09-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC STANDARD ED

  • Fixed component ID

    5608TPCS0

Applicable component levels

  • R422 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
23 March 2022