Fixes are available
APAR status
Closed as program error.
Error description
Brocade has added a new OUI value which is not recognized by TPC. Because of this information for these switches and their fabrics is not collected as expected resulting in functional limitations. This problem may be encountered with TPC or IBM System Director and VMcontrol. Here are some sample errors that can be seen with TPC or VMcontrol. These errors occur when there is a Brocade CIMOM agent already configured and monitoring the switches. The following samples of messaging may be found in the IBM System Director (VMcontrol) error-log-0.html: INFO Unable to start zoning transaction for fabricID: 10000027F8xxxxxx com.ibm.tpc.common.api.TPCServerException: BTAFM4501E No agent is available to configure the zoning on the fabric with ID 10000027F8xxxxxx Failed to start transaction on fabric 10000027F8xxxxxx. Check connection to switch(es) The following error shows up in TPC msgTPCDeviceServer.log: BTAFM4501E No agent is available to configure the zoning on the fabric with ID 10000027F806DA78. com.ibm.tpc.fabric.FabricManagerService startTransaction In the TPC GUI, you may experience unexpected messages in the probe logs indicating that the fabrics have limitations or you may not be able to get to the zone configuration panels due to a message stating no agent available, even when a CIMOM agent exists. Initial customer impact (low/med/high): Med
Local fix
Log into server with db2admin or db2inst1 (or equivalent, depending on platform) connect to TPCDB db2 connect to TPCDB db2 set schema tpc db2 "insert into T_RES_OUI values ('0027F8','Brocade')" Initiate Fabric discovery in TPC or (VMcontrol Farm and Switch inventory)
Problem summary
**************************************************************** * USERS AFFECTED: TPC 4.2.2.143 (FP3) and earlier or 5.1.1.0 * * and earlier users * **************************************************************** * PROBLEM DESCRIPTION: If you have a Brocade switch with the * * value of "0027F8" in the middle of * * the WWN, fabric probe will not * * recognize it as a Brocade and * * information about the switch and * * fabric will not be collected as * * expected. Performance monitoring * * functionality is not available for * * for these switches. This is most * * likely to affect newer Brocade switches.* **************************************************************** * RECOMMENDATION: * **************************************************************** -
Problem conclusion
The new OUI value of "0027F8" has been added to TPC with an association with Brocade for proper handling. The fix for this APAR is available in the following maintenance packages: | fix pack | 4.2.2-TIV-TPC-FP0004 - June 2013 | fix pack | 5.1.1-TIV-TPC-FP0001 - April 2013 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC90393
Reported component name
TPC STANDARD ED
Reported component ID
5608TPCS0
Reported release
422
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-21
Closed date
2013-02-23
Last modified date
2013-09-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC STANDARD ED
Fixed component ID
5608TPCS0
Applicable component levels
R422 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]