IBM Support

IC90364: DATAPOWER MQ BACKOUT DOES NOT WORK CORRECTLY WITH ALIAS QUEUES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the MQ Front Side Handler is connected to an alias Queue
    instead of a local input Queue, the MQ Backout Settings
    from the connected Queue Manager is  not  retrieved as
    expected.
    
    The result is that a failed Message remains in the local
    input Queue and is not  transferred to the configured
    Backout Queue.
    

Local fix

  • The workaround is to use a local input Queue instead of an alias
    input Queue.
    

Problem summary

  • Customers who use Alias Queues and enable the "Retrieve
    Backout Settings"  property in the MQ Front Side Handler are
    likely to see this
    problem.
    
    MQ Backout did not work correctly if MQ Front Side Handler
    connects and retrieves the backout setting from an Alias Queue.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC90364

  • Reported component name

    DTPWR INTGRAPL

  • Reported component ID

    DP905XI52

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-21

  • Closed date

    2013-04-25

  • Last modified date

    2013-05-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DTPWR INTGRAPL

  • Fixed component ID

    DP905XI52

Applicable component levels

  • R401 PSY

       UP

  • R402 PSY

       UP

  • R500 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: