APAR status
Closed as program error.
Error description
The following sequence of events might occur: * High priority device is active. * High device restarts or the interface is reconfigured. * Low device properly takes over after 10 second (hold time). * High device comes back. * High device gains link, but is still being blocked by spanning tree and thus has no connectivity. * High device becomes active. * Spanning tree unblocks the port, restoring connectivity. * High device is already active and sees another active device, so properly coups and forces an inappropriate takeover. * High device is Active again. * Low device is Standby again.
Local fix
Problem summary
Affected are customers using the Standby Control feature in a network where routers are configured to use the non-rapid variant of the Spanning Tree protocol. Slow spanning tree reconvergence after an appliance restart might cause network instability, where more appliances in the standby group become Active at the same time. This fix adds anone minute delay for every (re)started interface, which must pass before the interface can negotiate for being Active. This prevents the interface from taking over the VIP before a worst-case time of the Spanning Tree protocol reconvergence.
Problem conclusion
Fix is available in 4.0.2.13 and 5.0.0.8. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC90280
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-19
Closed date
2013-04-22
Last modified date
2013-09-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R402 PSN
UP
R500 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]