IBM Support

IC90200: TWO APPLIANCES CONFIGURED WITH THE SAME PHYSICAL ADDRESS ON THEIR INTERFACE COULD CAUSE AN ACTIVE APPLIANCE TO RESTART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Two appliances configured with the same physical (as opposed to
    virtual) address on their interface (ethernet or VLAN) could
    cause an active appliance to restart. This could happen
    after an import of an object from another appliance in the
    standby group.
    

Local fix

Problem summary

  • Affected are all users of the Standby Control feature, where
    their appliances' interfaces of a standby group have the
    same address.
    
    Such a condition might occur after importing
    an interface configuration from another appliance in the group
    and might cause an active appliance to restart.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC90200

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-14

  • Closed date

    2013-04-23

  • Last modified date

    2013-05-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R402 PSN

       UP

  • R500 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: