Closed as program error.
Error description
Users of TPC versions 4.2.x.x and below will find discrepancies between T_PRF_DSCONTROLLER table and the view. In 5.1.0 TPC, the T_PRF_DSCONTROLLER table was updated to fix the previous limitation that TPC did not store unique identifiers for DS* controllers. The data changed from having non-unique values of 0 and 1 to having specific ID values pertaining to the device. There are now ID values in the element_id column when a 5.1.x data collection is run on the device. The view needs updating to work correctly with the new data, and match the other PRF views, by returning the ID value in a Controller_ID (new) column.
Local fix
Call IBM support.
Problem summary
**************************************************************** * USERS AFFECTED: * * 5.1.0 and 5.1.1 customers that use the view * * TPCREPORTS.PRF_DSCONTROLLERS * **************************************************************** * PROBLEM DESCRIPTION: * * In 5.1.0 the data in table T_PRF_DSCONTROLLERS ELEMENT_ID * * field was updated to hold an actual ID value rather than * * just 0 or 1. However, the PRF_DSCONTROLLER view was not * * updated to handle values > 1 in that column. So these values * * were ignored and the CONTROLLER_NAME column produced by the * * View would be NULL for those rows containing real IDs. * **************************************************************** * RECOMMENDATION: * * Upgrade when available. * ****************************************************************
Problem conclusion
The view TPCREPORTS.PRF_DSCONTROLLERS was updated to handle ELEMENT_ID > 1. Now a new column will be created CONTROLLER_ID to contain the real IDs and it will be NULL when the older PM data is consumed. The CONTROLLER_NAME column will now either have the previous string values (when the ID is 0 or 1) or have UNAVAILABLE when ELEMENT_ID contains a real ID number. The fix for this APAR is targeted for the following maintenance package: | fix pack | 5.1.1-TIV-TPC-FP0001 - target March 2013 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC89948
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-30
Closed date
2013-02-01
Last modified date
2013-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
VIEW
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
R511 PSY
UP
Document Information