Error description

  • After physical restore of a whole system backup, you can use
    "onmode -s" or "onmode -m" to bring the database server up to
    "Quiescent" or "On-Line" mode without restoring logical logs.
    
    However, "onmode -s" and "onmode -m" commands will return before
    the database server is completely up in "Quiescent" or "On-Line"
    mode.  Depending on the sizes of your physical and logical logs,
    it can be several minutes before the database server is
    completely up in "Quiescent" or "On-Line" mode after the prompt
    has returned from the "onmode -s" or "onmode -m" command.  You
    must wait until the database server is completely up in
    "Quiescent" or "On-Line" mode before issuing any other commands.
    If the command "onmode -ky" is run before the database server is
    completely up in "Quiescent" or "On-Line" mode, subsequent
    "oninit" commands to bring up the database server may fail with
    the message "oninit: Fatal error in shared memory
    initialization" in the online.log .
    
    If you bring down the database server before it has fully
    changed to Quiescent or On-Line mode (after physical restore),
    subsequent "oninit -v" may show:
    ...
    Initializing dbspaces...succeeded
    Opening primary chunks...succeeded
    Opening mirror chunks...succeeded
    Validating chunks...succeeded
    Initialize Async Log Flusher...succeeded
    Starting B-tree Scanner...succeeded
    Initializing DBSPACETEMP list...succeeded
    Checking database partition index...FAILED <---
    oninit: Fatal error in shared memory initialization
    

Local fix

  • A possible workaround in this specific scenario is to run
    "oninit -r" to bring the database server back up in recovery
    mode, and then to run "onmode -s" or "onmode -m" to bring the
    server up to "Quiescent" or "On-Line" mode, being careful to
    wait until the database server is completely up before issuing
    any other commands (check online.log messages and "onstat -l"
    status).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of IDS 11.50 and above                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IDS-11.50.xC10                                     *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IDS-11.50.xC10
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC89895

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    B50

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-01-29

  • Closed date

    2017-06-15

  • Last modified date

    2017-06-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

  • RB50 PSY

       UP

  • RB70 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B50","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
15 June 2017