IBM Support

IC89817: DYNAMIC SERVICE WITH AN ATTACHMENT GETS A TIMEOUT ERROR FOR OTHER TRANSPORT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The web service client process always gets the following error:
    InternalError: Response not received before specified timeout
    reached. Closing connection at the dynamic service step.
    
    The same BP worked in previous versions and the web
    server provider was running without any change.
    This issue happens for every kind of WSDL with an attachment.
    A dynamic service with no attachment runs successfully without
    an HTTP connection. But for inline and mime attachments, the
    HTTP part is called also for OtherTransport.
    

Local fix

  • STRRTC - 361293
    MA / MA
    Circumvention: None
    

Problem summary

  • USERS AFFECTED:
    ALL
    
    PROBLEM DECRIPTION:
    DYNAMIC SERVICE WITH AN ATTACHMENT GETS A TIMEOUT ERROR FOR
    "OTHER TRANSPORT."
    
    PLATFORMS AFFECTED:
    ALL
    

Problem conclusion

  • RESOLUTION SUMMARY:
    THE TRANSPORT BINDING NEEDS TO BE ASSOCIATED WITH THE WSDL AT
    THE TIME OF CHECKING-IN A NEW WSDL.
    BY DOING THIS, THE TRANSPORT BINDING IS OBTAINED FROM THE
    WORKFLOW CONTEXT PARAMETERS AND THIS ALLOWS THE SOAP MESSAGES TO
    PROCESS CORRECTLY.
    
    DELIVERED IN:
    5020500_2
    5105
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC89817

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-01-24

  • Closed date

    2013-01-24

  • Last modified date

    2016-04-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R510 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]