APAR status
Closed as documentation error.
Error description
The Tivoli Storage Manager server have three ways while setting cleanFrequency option in drive definition. One of the way is setting it with gigabytes. but server documentation does not specify that H/W initiating cleaning drive can still be invoked when the option is set with gigabytes. The behavior should be noted along the explanation of gigabytes setting. Tivoli Storage Manager for Windows Version 6.3.3 Administrator's Reference Chapter 1. Administering the server from the command-line interface P.223 DEFINE DRIVE P.1191 UPDATE DRIVE ------------------------- CLEANFREQuency Specifies how often the server activates drive cleaning. This parameter is optional. The default is NONE. For the most complete automation of cleaning for an automated library, you must have a cleaner cartridge checked into the library's volume inventory. ... gigabytes Specifies, in gigabytes, how much data is processed on the drive before the server loads the drive with a cleaner cartridge. The server resets the gigabytes-processed counter each time it loads a cleaner cartridge in the drive. ------------------------- Tivoli Storage Manager Versions Affected: All supported versions for all platforms Customer/L2 Diagnostics (If Applicable) none Initial Impact: Low Additional Keywords: zz55 zz61 zz62 zz63 cleanFrequency drive gigabytes hardware cleaning
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Tivoli Storage Manager server users. * **************************************************************** * PROBLEM DESCRIPTION: See error desription. * **************************************************************** * RECOMMENDATION: * **************************************************************** *
Problem conclusion
The CLEANFREQUENCY parameter will be updated for the UPDATE DRIVE and DEFINE DRIVE commands: The parameter will include this note: Important: When CLEANFREQUENCY=gigabyte, drive cleaning can occur before the gigabyte setting is reached, if the drive notifies the device driver that a cleaning is necessary.
Temporary fix
Comments
APAR Information
APAR number
IC89809
Reported component name
TSM SERVER
Reported component ID
5698ISMSV
Reported release
63W
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-24
Closed date
2013-02-11
Last modified date
2013-02-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
SC23977501 | SC23977601 | SC23977701 | SC23977801 | SC23877901 |
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"63W","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
12 February 2013