APAR status
Closed as program error.
Error description
In some cases DataPower will log the following error message in the system log: "Error in stream. Descriptor number unavailable. Additional information: Read error (7)" Once this error occurs, the transaction will be lost or corrupted.
Local fix
It may be possible to eliminate the errors or reduce the error frequency by setting the persistent timeouts on HTTP(S) FSHs to a value higher than the usual interval between the requests.
Problem summary
Affected are customers using services with HTTP or HTTPS front side handlers processing POST requests over persistent connections configured with short persistent connection timeout. On rare occasions, if the overall duration of a POST request is comparable to the persistent connection timeout, the processing of a properly received, complete HTTP POST request may be aborted, which might result in an incomplete request sent to the backend. This is accompanied with a confusing error message similar to this: Error in stream. Descriptor number unavailable. Additional information: Read error (7) Descriptor is Ok (0)
Problem conclusion
The fix will be available in 4.0.1.16, 4.0.2.12 and 5.0.0.6 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC89568
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
401
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-16
Closed date
2013-02-25
Last modified date
2013-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R401 PSN
UP
R402 PSN
UP
R500 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022