Error description
DETAIL OF PROBLEM (include example(s) of error(s)): Hypervisor(s) showing errors, at the Datasource, such as 'Degraded Storage Path Redundancy', are not captured via the targets Probe job. Resulting in, no data collected from the Hypervisor. Additional and meaningful data needs to be captured regarding the current Hypervisor status as seen from the Datasource. RECREATE STEPS: Run Discovery and Probe to Hypervisor and view Results. Cross-reference the status seen at the Datasource for the Hypervisor. ________________________________________________________________ DB2 Version used for Server: 9.7.0.4 The defect is against component: 5608TC300 Server/Manager build/release (TPC): 5.1.0 Agent build/release (TPC): Server/Manager (OS): WIN 2008 Agent (OS): ________________________________________________________________ Problem as described by customer: Hypervisors do not show data after Probe. Initial customer impact (low/med/high): med
Local fix
TBD
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.1.0 users who have hypervisor(s) managed by vcenter in * * their environment * **************************************************************** * PROBLEM DESCRIPTION: * * A probe does not collect data about a hypervisor that * * generates alarms in VMware vCenter. In Tivoli Storage * * Productivity Center, the status of the probe might be * * successful even though it did not collect any data about the * * hypervisor. * **************************************************************** * RECOMMENDATION: * * In VMware vCenter, managed hypervisors generate alarms or * * alerts that are based on their status. When a probe collects * * data about hypervisors, Tivoli Storage Productivity Center * * detects if hypervisors have alarms that are red alerts. To * * avoid problems when collecting data, accept the alarms that * * are red alerts. * ****************************************************************
Problem conclusion
A code change was made so that if there are alarms on the vcenter about a specific hypervisor problem , the probe is successful only if data collection was successful. The fix for this APAR is targeted for the following maintenance package: | fix pack | 5.1.1.1-TIV-TPC-FP0001 - target March 2013 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC86567
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-18
Closed date
2012-12-06
Last modified date
2012-12-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PROBE
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
Document Information
Modified date:
23 March 2022