IBM Support

IC83834: FCM FOR DB2 BACKUPS WITH DB2 AUTOMATIC STORAGE FAIL WITH FMM8344E PATH <PATH> IS LISTED MORE THAN ONCE FOR PARTITIONING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Tivoli Storage FlashCopy Manager for DB2 backups can fail when
    using DB2 Automatic Storage if the same paths are specified
    multiple times upon setting up the database.  This is a valid
    DB2 configuration, but Flashcopy Manager does not support this.
    This needs to be documented.
    Initial impact: Medium
    Platforms Affected: FlashCopy Manager for DB2 2.1, 2.2, and 3.1
    L2 diagnostics:
    A client trace will shows a series of paths specified multiple
    times:
    09:45:03.460   400 (1) esd-clientinterfacevalues.cpp:1015
    iter.value().data()=erpprd1
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/log_dir/NODE0000/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/db2prd/NODE0000/SQL00001/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/db2prd/NODE0000/sqldbdir/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata1/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata1/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata1/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata1/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata2/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata2/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata2/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata2/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata3/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata3/db2prd/NODE0000/PRD/
    09:45:03.460   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata3/db2prd/NODE0000/PRD/
    09:45:03.461   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata3/db2prd/NODE0000/PRD/
    09:45:03.461   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata4/db2prd/NODE0000/PRD/
    09:45:03.461   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata4/db2prd/NODE0000/PRD/
    09:45:03.461   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata4/db2prd/NODE0000/PRD/
    09:45:03.461   400 (1) esd-db2BA.cpp:1798
    pCurrentPath->path=/db2/PRD/sapdata4/db2prd/NODE0000/PRD/
    .
    Flashcopy Manager assumes the paths are redundant and will fail.
    Additional Keywords: partitioning
    

Local fix

  • DB2 configuration needs to be redesigned.  In the example trace
    above, an additional subdirectory can be introduced, for
    example:
    /db2/PRD/sapdata1/cont1/db2prd/NODE0000/PRD/
    /db2/PRD/sapdata1/cont2/db2prd/NODE0000/PRD/
    /db2/PRD/sapdata1/cont3/db2prd/NODE0000/PRD/
    /db2/PRD/sapdata1/cont4/db2prd/NODE0000/PRD/
    These 4 paths (including the cont* directory) could then be used
    to configure Automatic Storage in a way so that Flashcopy
    Manager sees them as distinct paths.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Tivoli Storage FlashCopy    *
    *                 Manager for DB2 who back up                  *
    *                 data stored on DB2 Automatic Storage.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: See ERROR DESCRIPTION                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    *
    

Problem conclusion

  • This APAR will not be fixed. A problem can occur when using
    IBM Tivoli Storage FlashCopy Manager to protect data stored on
    DB2 Automatic Storage.
    Actions to prevent or solve such situations are outlined in
    the 'Local fix' section.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC83834

  • Reported component name

    FLSHCPY DB2 AGE

  • Reported component ID

    5608AC6DB

  • Reported release

    31A

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-29

  • Closed date

    2012-08-30

  • Last modified date

    2012-08-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS36V9","label":"Tivoli Storage FlashCopy Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"31A","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
30 August 2012