Direct links to fixes
4.6.0.5-SterlingConnectDirectSDK-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectSDK-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
4.6.0.6-SterlingConnectDirectSDK-x86-fp0006-if018
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
Error Description lcu.bat fails to run when installed from Sterling Connect:Direct for Windows SDK: The system cannot find the path specified.
Local fix
Local Fix STRRTC - 323115 SF / SF Circumvention: Edit the lcu.bat file manually and set cdInstallDir to the fully qualified path of the installation directory, typically: set cdInstallDir=C:\Program Files\Sterling Commerce\Connect Direct v4.6.00
Problem summary
Users Affected: Sterling Connect:Direct for Windows SDK 4.6.0 Problem Description: lcu.bat fails to run when installed from Sterling Connect:Direct for Windows SDK: "The system cannot find the path specified." Platforms Affected: Windows
Problem conclusion
Resolution Summary: Updated the SDK installer to trigger lcu.bat customization. Delivered In: Sterling Connect:Direct for Windows SDK 4.6.0.2_iFix004
Temporary fix
na
Comments
APAR Information
APAR number
IC82703
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
460
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-04-17
Closed date
2012-04-24
Last modified date
2012-04-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSRRVY","label":"Sterling Connect:Direct for Microsoft Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.6","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: