IBM Support

IC82695: CHECKING VOLUMES INTO ACSLS LIBRARY MAY CAUSE SERVER TO CRASH AT LIBQUVO

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem Description:
    
    Checking volume into a ACSLS library may cause Tivoli Storage
    Manager Server to crash with the following stack:
    
    LibQuVol(??, ??, ??) at 0x100ba8ad8
    mmsacsls.ManualCheckinVolume(??) at 0x100ba67d8
    AcslsCheckinVolume(??) at 0x100ba5b88
    MmsLtsCheckinVolume@AF84_45(??, ??) at 0x10045aee4
    CheckinThread(??) at 0x10049d580
    StartThread(??) at 0x10002075c
    
    L2/Customer Diagnostic:
    
    The crash can happen if passing more than one volume_name in the
    checkin command like this:
    
    checkin libv ACSLS_LIB volume1 volume2 status=private/scratch
    
    Note:
    Above example is an incorrect command syntax, the correct
    command to checkin more than one volume is using Vollist or
    Volrange option.
    
    .
    Platform Version Affected:
    Tivoli Storage Manager Server all supported version on all
    platforms using ACSLS library
    .
    
    
    
    
    
    
    .
    

Local fix

  • Local fix:
    Use  correct command to checkin volume, for example:
    
    checkin libv ACSLS_LIB search=yes status=private/scratch
    volist=volume1,volume2
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli Storage Manager server users of   *
    *                 ACSLS.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: See error description.                  *
    ****************************************************************
    * RECOMMENDATION: Apply fixing level when available. This      *
    *                 problem is currently projected to be fixed   *
    *                 in levels 6.3.3. Note that this is           *
    *                 subject to change at the discretion of IBM.  *
    ****************************************************************
    *
    

Problem conclusion

  • This problem was fixed.
    Affected platforms:  AIX, HP-UX, Solaris, Linux, and Windows.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC82695

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    63A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-19

  • Closed date

    2012-06-18

  • Last modified date

    2012-06-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R62A PSY

       UP

  • R62H PSY

       UP

  • R62L PSY

       UP

  • R62S PSY

       UP

  • R62W PSY

       UP

  • R63A PSY

       UP

  • R63H PSY

       UP

  • R63L PSY

       UP

  • R63S PSY

       UP

  • R63W PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"63A","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]