Direct links to fixes
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if007
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if010
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if015
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if017
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if022
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
Sterling Connect:Direct for Windows 4.4.00 Patch 071
Sterling Connect:Direct for Windows 4.4.01 Patch 015
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
When logging LSMR003I, LSMR014I or LSMR015I errors for a long RUN TASK/JOB command, the error message may get truncated inappropriately. The Connect:Direct Java Application Interface (CDJAI) fails with a KQVString.parse() exception when retrieving this message in a Select Statistics command.
Local fix
Local Fix STRRTC - 318639 SF / SF Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.4.00 Sterling Connect:Direct for Windows 4.4.01 Sterling Connect:Direct for Windows 4.4.00 Sterling Connect:Direct for Windows 4.5.01 Sterling Connect:Direct for Windows 4.6.0 Problem Description: When logging LSMR003I, LSMR014I or LSMR015I errors for a long RUN TASK/JOB command, the error message may get truncated inappropriately. The Connect:Direct Java Application Interface (CDJAI) fails with a KQVString.parse() exception when retrieving this message in a Select Statistics command. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Reworked the code that does the statistics logging for these error messages. A long command value will be truncated and preceded with "..." for the &EXE substitution data as needed, ensuring balanced double-quotes. The full sysopts will now be logged in the correct field (SOPT instead of SFIL). In addition, the OS error of the failure will now be logged in the feedback code. As a side fix, an issue for was resolved, where the user's profile and environment was not unloaded after LSMG249I occurred. Delivered In: Sterling Connect:Direct for Windows 4.4.00 Build 069 Fix 147 Sterling Connect:Direct for Windows 4.4.01 Build 012 Fix 35 Sterling Connect:Direct for Windows 4.4.00 Build 051 Fix 82 Sterling Connect:Direct for Windows 4.5.01 Build 017 Fix 49 Sterling Connect:Direct for Windows 4.6.0.2_iFix003
Temporary fix
Apply interims fix
Comments
APAR Information
APAR number
IC82617
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
450
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-04-11
Closed date
2012-04-26
Last modified date
2012-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
25 August 2023