APAR status
Closed as program error.
Error description
When using a Load Balancer Group (LBG) to dynamically retrieve Workload Management Information for WAS (WebSphere Application Server) cell members, an unexpected restart can occur if the next LBG member is chosen at the same time that DataPower detects a WAS cell member has went down.
Local fix
Create an LBGroup with static members (as opposed to the WLM dynamic members)
Problem summary
Affected are DataPower customers using Load Balancer Groups enabled to retrieve workload management information Problem Summary: Restart might occur if a load balancer group member is removed from the group while requests are being routed to this member.
Problem conclusion
The fix is available in 3.8.2.12, 4.0.1.10 and 4.0.2.6.
Temporary fix
Comments
APAR Information
APAR number
IC82347
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-29
Closed date
2012-04-19
Last modified date
2012-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]