IBM Support

IC81829: DATAPOWER MIGHT RESTART UNDER LOAD WHEN USING MQ FRONT SIDE HANDLER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DataPower might restart under load when using MQ Front Side
    handler and the memory throttle limit is reached.
    
    The log may show the following warning from the MQ FSH just
    before the reboot:
    
    mq,warn,source-mq,fsh_ABC,10810,,0x80e00028,,,"'MYQ_GRP'
    throttling due to low memory condition"
    

Local fix

Problem summary

  • Affected are customers who use an MQ front side handler in a
    stress test.
    
    The appliance might restart if it hits a memory throttle.
    

Problem conclusion

  • The fix is available on 4.0.1.10 and 4.0.2.6.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC81829

  • Reported component name

    DATAPWER B2B XB

  • Reported component ID

    DP1234B2B

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-03-05

  • Closed date

    2012-04-16

  • Last modified date

    2012-07-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPWER B2B XB

  • Fixed component ID

    DP1234B2B

Applicable component levels

  • R401 PSY

       UP

  • R402 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSQ3J2","label":"WebSphere DataPower B2B Appliance XB60"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
24 July 2012