IC81790: UNDO MAY NOT WORK AS EXPECTED FOR AAA POLICIES USING LTPA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When modifying a AAA Policy object that uses LTPA in the
    PostProcessing step, the undo feature may not work as expected.
    The change will be reverted, but the object will be down with
    an error about an invalid configuration.
    

Local fix

  • Reapply the object after running undo to bring the object back
    up.
    

Problem summary

  • Affected customers are those using a AAA policy configured with
    Generate LTPA Token in the PostProcessing step. The Undo
    function in the WebGUI causes the object to be marked down.
    

Problem conclusion

  • Undo now reverts the change and then the AAA object transitions
    back to op state up.
    
    The fix is available in 4.0.1.9 and 4.0.2.5.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC81790

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-03-02

  • Closed date

    2012-03-19

  • Last modified date

    2012-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R401 PSY

       UP

  • R402 PSY

       UP

  • R500 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 February 2022