IBM Support

IC80520: SCHEMA VALIDATION FAILURE WHEN COMPLEX TYPE ELEMENT HAS EXTRA WHITE SPACES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DataPower fails to schema validate a complex type element that
    has more that 4096 continuous white spaces in the element. An
    example of such element:
    
     <Test>
      [More than 4096 white spaces]
      <data>123</data>
     </Test>
    
    The XML document will fail schema validation and an error
    message similar to the one below will be logged:
    
    cvc-complex-type 2.3: element {http://test.org/some/ns/2}Test of
    type
    {http://test.org/some/ns/2}Test_Type may not have text content
    

Local fix

  • Reduce the number of continuous white spaces to 4096 or less.
    

Problem summary

  • Affected is Schema validation of documents with text nodes
    containing significant amounts of whitespace.
    
    Validation errors were reported for whitespace for more than
    4096 characters.
    

Problem conclusion

  • Fix is available in 3.8.2.10, 4.0.1.7 and 4.0.2.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC80520

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    401

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-12-20

  • Closed date

    2012-01-18

  • Last modified date

    2012-02-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R382 PSY

       UP

  • R401 PSY

       UP

  • R402 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]