IBM Support

IC80348: DUPLICATE RECORDS FOR A TIVOLI STORAGE MANAGER CLIENT MAY APPEAR IN PVU ESTIMATE REPORTING

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Duplicate records for a node may appear in PVU estimate
    reporting when the node's CPU has a match in the PVU
    table for both the specific CPU model number and an entry for a
    default CPU model number. Default
    CPU model numbers in the PVU table are indicated by a blank
    internal value.
    
    Example:
    
    A lookup is done in the pvu table for the following cpu:
    PROC_VENDOR = Intel
    PROC_MODEL = 5140
    PROC_COUNT=1
    PROC_TYPE=2
    PROC_BRAND = Dual-Core Xeon
    
    When the PVU table has a match for both the specific CPU model
    (example Model
    internal-value="5140"), and a default match (Model
    internal-value=""), the sql left outer join used
    in the PVU estimate reporting will generate 2 records in the
    result set instead of 1. The result set should
    only include one record with a match to "5140".
    
    PVU table entries:
    
    <VU-entry Processor-description="Intel(R) Xeon(R) Multi-core
    3000-3399 or 5000-5499 or 7000-7499">
    <Vendor displayable-value="Intel(R)" internal-value="Intel"/>
    <Brand displayable-value="Xeon(R)" internal-value="Dual-Core
    Xeon"/>
    <Type displayable-value="Multi-core" internal-value="2"/>
    <Model displayable-value="3000-3399 or 5000-5499 or 7000-7499"
    internal-value="5140"/>
    <Value-units>50</Value-units>
    <Start-date>2009-04-01</Start-date>
    <End-date>9999-12-31</End-date>
    <Tool-version>7.1.0.0.0</Tool-version>
    </VU-entry>
    <VU-entry Processor-description="Intel(R) Xeon(R) or Pentium(R)
    Multi-core All Existing">
    <Vendor displayable-value="Intel(R)" internal-value="Intel"/>
    <Brand displayable-value="Xeon(R) or Pentium(R)"
    internal-value="Dual-Core Xeon"/>
    <Type displayable-value="Multi-core" internal-value="2"/>
    <Model displayable-value="All Existing" internal-value=""/>
    <Value-units>50</Value-units>
    <Start-date>2007-01-18</Start-date>
    <End-date>9999-12-31</End-date>
    <Tool-version>7.1.0.0.0</Tool-version>
    </VU-entry>
    
    
    Tivoli Storage Manager Versions Affected:
    Tivoli Storage Manager 6.3.0.0
    
    
    Initial Impact:
    Medium
    
    
    Additional Keywords:
    TSM PVU duplicate record
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli Storage Manager server users.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: See error description.                  *
    ****************************************************************
    * RECOMMENDATION: Apply fixing level when available. This      *
    *                 problem is currently projected to be fixed   *
    *                 in levels 6.3.1.                             *
    *                 Note that this is subject to change at       *
    *                 the discretion of IBM.                       *
    ****************************************************************
    *
    

Problem conclusion

  • This problem was fixed.
    Affected platforms:  AIX, HP-UX, Solaris, Linux and Windows.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC80348

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    63W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-12-13

  • Closed date

    2012-01-16

  • Last modified date

    2012-01-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

  • R63A PSY

       UP

  • R63H PSY

       UP

  • R63L PSY

       UP

  • R63S PSY

       UP

  • R63W PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"63W","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
16 January 2012