IBM Support

IC79720: INCORRECT MESSAGE SENT WHEN SMO IS CONSTRUCTED IN A CUSTOM MEDIATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a SMO is constructed in a custom mediation, and when it has
    not been altered in the flow by a subsequent mediation and is
    then sent to an import with the same type of binding as the
    export which initiated the flow, the wrong message might be
    sent to the import instead of the newly edited SMO from the
    custom mediation.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Websphere Enterprise Service Bus    *
    *                 or Websphere Process Server v7.0 or v7.5.0   *
    *                 who use custom mediation primitives may,     *
    *                 under certain circumstances, encounter       *
    *                 this issue.                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect message sent when the SMO     *
    *                      is constructed within a custom          *
    *                      mediation.                              *
    ****************************************************************
    * RECOMMENDATION: If you encounter this problem then you are   *
    *                 advised to install the code fix associated   *
    *                 with  this APAR.                             *
    ****************************************************************
    When a SMO is constructed in a custom mediation, and when it
    has not been altered in the flow by a subsequent mediation and
    is then sent to an import with the same type of binding as the
     export which initiated the flow, the wrong message might be
    sent to the import instead of the newly edited SMO from the
    custom mediation.
    

Problem conclusion

  • The code was modified to ensure that the new SMO is sent to
    the import
    
    This code fix was targeted to be included in the following fix
    packs:
    
    7.0.0 Fix Pack 5 (v7.0.0.5)
    7.5.0 Fix Pack 2 (v7.5.1.1)
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC79720

  • Reported component name

    WEB ESB FOR WIN

  • Reported component ID

    5724I8200

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-11-10

  • Closed date

    2012-01-27

  • Last modified date

    2012-01-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEB ESB FOR WIN

  • Fixed component ID

    5724I8200

Applicable component levels

  • R100 PSN

       UP

  • R200 PSN

       UP

  • R300 PSN

       UP

  • R612 PSN

       UP

  • R620 PSN

       UP

  • R700 PSY

       UP

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7J6S","label":"WebSphere Enterprise Service Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]