APAR status
Closed as program error.
Error description
With heavy load coming in to a DataPower FTP Server Front Side Handler, memory might not be reclaimed.
Local fix
Restart appliance when memory usage exceeds 50-60% to recover unreclaimed memory.
Problem summary
Affected is the use of FTP server front side handler (FSH) on the appliance. When multiple files are sent over an established connection to the FSH, memory might not be freed.
Problem conclusion
The fix is available in 3.8.0.18, 3.8.1.18, 3.8.2.9, 4.0.1.6 and 4.0.2.2
Temporary fix
Comments
APAR Information
APAR number
IC79541
Reported component name
DATAPWER B2B XB
Reported component ID
DP1234B2B
Reported release
381
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-10-31
Closed date
2011-12-05
Last modified date
2012-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPWER B2B XB
Fixed component ID
DP1234B2B
Applicable component levels
R381 PSY
UP
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSQ3J2","label":"WebSphere DataPower B2B Appliance XB60"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
31 March 2012