IC78472: CERTAIN PROCESSING INSTRUCTIONS MIGHT CAUSE DEVICES WITH NO XML ACCELERATOR TO RESTART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Certain processing instructions on incoming request messages
    might cause a restart of an appliance without an XML
    accelerator.
    

Local fix

Problem summary

  • Affected are customers of devices without an XML accelerator
    using a DataPower XML processing service.
    
    Certain processing instructions on incoming request messages
    might cause a restart of the appliance.
    

Problem conclusion

  • Fix is available in 3.8.0.16, 3.8.1.16, 3.8.2.7, 4.0.1.4,
    4.0.2.0 and XE82 1.0.0.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC78472

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    381

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-06

  • Closed date

    2011-09-20

  • Last modified date

    2011-10-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R100 PSY

       UP

  • R380 PSY

       UP

  • R381 PSY

       UP

  • R382 PSY

       UP

  • R401 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]