IBM Support

IC78400: LOG MESSAGE 0X08040008d "BINARY DATA: MAXIMUM MESSAGE SIZE EXCEEDED" LOGGED ONLY IN DEFAULT DOMAIN

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Log message 0x08040008d ?Binary Data: Maximum message size
    exceeded? is logged only in the system log of the default
    domain.  It should be logged in the application domain where the
    corresponding maximum message size was configured for a specific
    service object.
    

Local fix

  • Review the system log from the default domain when searching for
    this log message.
    

Problem summary

  • When using max-message-size service parameter to limit the
    maximum accepted binary message size, the accompanying log
    message indicating the message has been rejected due to exeeding
    this limit is not logged in the application
    domain's log, showing in the default domain's log instead.
    Additionally, the message logged is identical to the case when a
    message has been rejected due to insufficient memory. No
    information about the service and transaction ID is provided.
    

Problem conclusion

  • The fix is available in 3.8.1.18, 3.8.2.9, 4.0.1.6 and 4.0.2.2.
    

Temporary fix

  • Check also the default domain's log when looking for cases of
    rejected oversize binary messages.
    

Comments

APAR Information

  • APAR number

    IC78400

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-30

  • Closed date

    2011-11-30

  • Last modified date

    2011-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R381 PSN

       UP

  • R382 PSN

       UP

  • R401 PSN

       UP

  • R402 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]