APAR status
Closed as program error.
Error description
Appliance restart might occur during a binary transform with a specific FFD file where the output needs to be interrupted and output type is PIPE. An example of an FFD construct that needs an output interrupt is the countField feature.
Local fix
Change the output of the binary transform from PIPE to a named context.
Problem summary
Affected is the use of a binary transform action with a specific FFD file where the output is set to the PIPE context. Appliance might restart if the binary transformation code requires an interrupt of output, for example by the FFD countField feature.
Problem conclusion
Fix is available in 3.8.2.7, 4.0.1.2, 4.0.2.1 and XE82 1.0.0.2
Temporary fix
Comments
APAR Information
APAR number
IC76725
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
380
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-02
Closed date
2011-08-27
Last modified date
2011-11-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R100 PSY
UP
R382 PSY
UP
R401 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]