IBM Support

IC76041: PCOM: INTERMITTENT TWO SECOND DELAY BETWEEN EHLLAPI FUNCTION CALLS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • EHLLAPI application users experience intermittent delays or slow
    down in performance. Traces show a 2 second round trip time for
    each EHLLAPI function call for two minutes or more. Then the
    delay goes away and the EHLLAPI function calls return to normal
    sub-second round trip time.
    
    This happens on PCOM 5.9.0 and 5.9.7.1 levels.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All EHLLAPI application users                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Intermittent 2 second delay using       *
    *                      EHLLAPI application.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Multi threaded EHLLAPI applications experience intermittent
    hang and a consistent 2 second delay in EHLLAPI calls.
    

Problem conclusion

  • When a user application makes a EHLLAPI call, PCOMM creates a
    memory block. This is done once for an instance of the user
    application (one per process). If the first EHLLAPI call is
    made through multiple threads, PCOMM needs synchronization to
    allow only the first thread to create this memory block. The
    release of the lock for this synchronization was not done
    cleanly. PCSHLL32.DLL has been changed to resolve this.
    
    Fix scheduled for PCOM 5.9.8 refresh pack
    Fix scheduled for PCOM 6.0.3 refresh pack
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC76041

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I7000

  • Reported release

    590

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-27

  • Closed date

    2011-04-28

  • Last modified date

    2012-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • PCSHLL32
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R590 PSY IP23349

       UP12/05/09 I 1000

  • R601 PSY

       UP