Error description

  • On Linux platform with KAIO, any read and write failure can go
    unnoticeable by Informix. The IO failure will not reflect in the
    online.log and Informix will not bring chunks off-line, which
    could lead to data corruption and other problems.
    

Local fix

  • This can be observed only with KAIO enabled. If you turn off
    KAIO it might provide a temporary solution, but this can have
    unwanted effects on the I/O performance.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All platforms                                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IBM Informix Server 11.50.xC9                      *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IBM Informix Server 11.50.xC9
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC75881

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    B50

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-04-19

  • Closed date

    2017-06-19

  • Last modified date

    2017-06-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

  • RB50 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B50","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
19 June 2017